Immersion Element Steam Boilers (IS)

The IS range of boilers is available from 36 kW to 2106 kW – steam output up to 3345 kg/h (7374 lb/h) from and at 100°C, at working pressures up to 10.3 barg (150 psig). Higher pressures are available.

With their large water capacity, IS boilers act as steam accumulators. This feature enables the boiler to meet steam demands in excess of the rated output. As an example, the IS7 operating at 10.3 barg (150 psig) can generate twice rated output for 7 minutes for a pressure reduction of 3.4 bar (50 psi).

The boilers are available as a free-standing boiler complete with all controls mounted on a mild steel chassis with a separately mounted feedwater pump, or as a packaged unit with high level feedwater tank.

The standard steam output rating of our IS Immersion Element Steam Boiler range from a 3 phase 415 volt supply operating from and at 100°C is shown below:

Model Steam Output (Kg/Hr) Load Rating (kW) Current Per Phase (Amps)
IS3 57 36 51
IS5 86 54 75
IS7 113 72 101
IS9 143 90 126
IS10 170 108 151
IS12 200 126 176
IS14 229 144 200
IS16 257 162 226
IS18 286 180 250
IS20 320 202 282
IS24 385 243 339
IS28 450 283 395
IS32 515 324 451
IS36 575 364 508
1S40 640 405 564
IS44 705 445 620
IS48 770 486 677
IS52 835 526 733
IS56 900 567 789
IS64 1030 648 902
IS72 1155 729 1015
IS81 1285 810 1127
IS89 1415 891 1240
IS97 1545 972 1353
IS105 1670 1053 1465
IS113 1800 1134 1578
IS129 2060 1296 1803

Technical Specification – IS Boiler

Electrical Supply:

3 phase, 4 wire (voltage up to 690V and frequency 50/60Hz to be specified)

Vessel:

Built to BS5500 and independently inspected by Zurich Insurance. Full certification is issued with completed boilers.

Standard Pressures:

  • Working Pressure 10.3 barg (150 psig)
  • Design Pressure 11.4 barg (165 psig)
  • Hydraulic Test Pressure 22.7 barg (330 psig)

Optional Extras:

  • Tank on Stand/Skid Mounted
  • Blowdown Vessel
  • Automated Tank Controls
  • Dosing Set with Pump & Tank
  • Sample Cooler
  • 3"/4" Vent Head
  • Timer Controlled Blowdown
  • TDS Controlled Blowdown
  • Water Softener
  • Thyristor Load Regulation
  • Earth Fault Protection
  • Magnetic Water Level Gauge
  • PLC Controller – remote monitoring and diagnostics
  • High Pressure
  • Clean Steam – Stainless Steel
  • Remote Cabinet
  • Opposite Hand
  • Duty Standby